Educational and professional workstation for the rigorous step-by-step analysis and design of reinforced concrete beams at ultimate flexural and shear limit states per ACI 318.
In this section the given values will be compared with the limitation according to the selected Code, Since this program is for educational purpose even if the given data are beyond the limitation the analysis still will be done
According to the code the bar spacing must be larger or equal to min bar spacing otherwise the bar arrangement must be changed.
According to the code the bar spacing must be larger or equal to min bar spacing otherwise the bar arrangement must be changed.
According to the code provided tension steel less than the min steel area is not permitted
According to the code provided tension steel more than the maximum steel area is not recommended
In this section we will find the ultimate flexural moment capacity of the beam, i.e the maximum allowable applied moment
| $a$ | = depth of equivalent rectangular stress block |
| $A_s$ | = area of longitudinal tension reinforcement |
| $A_s'$ | = area of compression reinforcement |
| $A_{sf}$ | = steel area required to balance the flange overhang |
| $A_{sw}$ | = steel area required to balance the web compression |
| $A_{s,min}$ | = minimum area of flexural reinforcement |
| $A_{s,balance}$ | = balanced area of flexural reinforcement at balanced failure i.e., the tension reinforcement is just reaching its yield strain, at the same time the extreme concrete compression fiber is reaching the maximum useable compression strain 0.003 |
| $b$ | = width of compression face or total flange width |
| $b_w$ | = width of web (stem) |
| $h_f$ | = thickness of flange |
| $c$ | = distance from extreme compression fiber to neutral axis |
| $c_c$ | = clear cover of reinforcement or layer spacing |
| $d$ | = distance from extreme compression fiber to centroid of longitudinal tension reinforcement |
| $d'$ | = distance from extreme compression fiber to centroid of longitudinal compression reinforcement |
| $d_t$ | = distance from extreme compression fiber to centroid of extreme layer of longitudinal tension reinforcement |
| $E_s$ | = modulus of elasticity of reinforcement and structural steel |
| $f'_c$ | = specified compressive strength of concrete |
| $f_y$ | = specified yield strength for longitudinal reinforcement |
| $f_s$ | = stress in the tension reinforcement |
| $f_s'$ | = stress in the compression reinforcement |
| $h$ | = overall height, or depth of member |
| $M_u$ | = factored moment at section |
| $N_c$ | = total internal compressive force |
| $N_{c1}$ | = internal compressive force from concrete resistance (flange or rectangular block) |
| $N_{c2}$ | = internal compressive force from steel or web concrete resistance |
| $N_t$ | = total internal tensile force |
| $N_{t1}$ | = internal tensile force from bottom tension reinforcement |
| $N_{t2}$ | = internal tensile force from top reinforcement when $c < d'$ (top steel in tension) |
| $f_{s2}$ | = tensile stress in top reinforcement when $c < d'$ |
| $\beta_1$ | = factor relating depth of equivalent rectangular compressive stress block to depth of neutral axis |
| $\varepsilon_{cu}$ | = maximum strain at extreme concrete compression fiber "0.003" |
| $\varepsilon_s$ | = tensile strain in center of longitudinal tension reinforcement at nominal strength |
| $\varepsilon_s'$ | = compressive strain in center of longitudinal compression reinforcement at nominal strength |
| $\varepsilon_{s2}$ | = tensile strain in top reinforcement when $c < d'$ (top steel in tension) |
| $\varepsilon_t$ | = net tensile strain in extreme layer of longitudinal tension reinforcement at nominal strength |
| $\phi$ | = strength reduction factor |
| $Z$ | = internal lever arm between resultant compressive and tensile forces ($d - a/2$) |
| $Z_1, Z_2$ | = internal lever arms for component forces in doubly reinforced or flanged sections |